DBW Close Rate Damping

DBW Close Rate Damping

DBW Close Rate Damping Table


The damping level applied to the electronic throttle while closing while engine demand is 2.5% or greater. To disable this set to zero. The maximum damping available is 10.
    • Related Articles

    • DBW Lift Rate Damping

      DBW Lift Rate Damping The damping level applied to the electronic throttle while closing when engine demand is lower than 2.5%. To disable this set to zero. Maximum damping available is 10.
    • DBW Open Rate Damping

      DBW Open Rate Damping Table This table sets The damping level applied to the electronic throttle when opening. This is used to soften the feel of the throttle to make it less sensitive to sudden movements, with higher numbers giving more dampening. ...
    • Ignition Correction Attack Rate

      Attack Correction The Attack Rate table controls the rate in Degrees Per Engine Cycle at which the ignition timing can be advanced from a retarded value to a more advanced value. It is often used to smooth out the change in engine torque when there ...
    • Haltech Elite ECU and Drive-By-Wire

      Drive-By-Wire (DBW) is one of the most anticipated features on the new Haltech Elite Series ECUs, but it’s the implementation of the DBW system that really makes the Elite Series stand out from the crowd. How DBW works To put it simply; in a DBW ...
    • Elite 1500/2500 DBW Wiring Information