Ignition Decay Correction Rate

Ignition Decay Correction Rate

Decay Correction

The Decay Rate table controls the rate in Degrees Per Engine Cycle at which the ignition timing can be retarded from an advanced value to a more retarded value. This table is not often used compared to the Attack table, so default values are quite high - around 50.
Up to 3D mapping is available with these table. (Default = Disabled)

    • Related Articles

    • Ignition Correction Attack Rate

      Attack Correction The Attack Rate table controls the rate in Degrees Per Engine Cycle at which the ignition timing can be advanced from a retarded value to a more advanced value. It is often used to smooth out the change in engine torque when there ...
    • Ignition Tuning

      Ignition Tuning Ignition Angle Lock Mode Allows the ignition advance to be fixed at a determined value to allow calibration of the TDC Offset. All ignition tables and corrections are ignored when this is active, and the ignition advance will not ...
    • Tuning

      The Transient Throttle tables should be set up after the fuel and maps are correctly tuned for steady load running. Attempting to smooth out engine transients before the fuel maps have been optimised for steady state running may become confusing. ...
    • Coolant Temp Ignition Correction

      Coolant Temp Correction This table controls how many degrees of ignition timing correction will be applied for a given Coolant Temperature, and is often mapped against engine load as well. Positive values will advance timing by that amount, negative ...
    • Ignition Gear Correction

      Gear Correction The amount of ignition timing correction for each gear. Positive values will advance timing by that amount, negative values will retard timing by that amount. This option is only available when a Gear Position Sensor or calculation ...