Generic Timer
A Generic Timer is used when a channel or function is required over a time base, and activated by another channel or condition. Typical uses for Generic Timers are for drag racing launch programming, or programming delays for custom functions.
Settings
Name - Sets the name that is to be used for the Generic Timer. This name will be used when searching for channels throughout the system.
Start Condition
Select which ECU channel and its conditions will start the timer.
Select - Selection of the ECU channel to be used to start the timer.
Maths - A selection of Equal To, Not Equal To, Greater Than, Less Than, Greater Than Or Equal To, Less Than Or Equal To that is to be used to start the timer.
Value - The value the maths must meet.
Reset Condition
Select which ECU channel and its condition will reset the timer, and allow the Generic Timer to start again if Start Conditions are met.
Select - Selection of the ECU channel to be used to reset the timer.
Maths - A selection of Equal To, Not Equal To, Greater Than, Less Than, Greater Than Or Equal To, Less Than Or Equal To that is to be used to reset the timer.
Value - The value the maths must meet.