Nitrous Override
Nitrous Overrides can be used to activate the nitrous stage regardless of the activation conditions and modes. Most commonly this is either in an engine purge situation (commonly known as 'burping'), or when the driver would like to activate the stage with a button press.
Nitrous Override
Minimum Engine Running Time -
This is the minimum time the engine must have been running for before the override function can be triggered.
Minimum TPS -
The throttle position must be equal to or greater than this value for the override function to be triggered.
Minimum RPM -
The engine RPM must be equal to or greater than this value for the override function to be triggered.
Switch Enable -
This allows the use of an input pin to trigger the override function. If disabled, you can use the Conditional Enable.
Conditional Activation
The override function can also be triggered using conditions. These conditions can be used With or Without the override switch.