Selector Position
The Selector Position node is only available if Selector Position Type is set to Voltage Input in the Gear Detection function
This node allows for the Selector Position Sensor calibration to be created. By pressing the Calibrate button with the gear selector in the listed position, the Nominal Voltage value will be filled out automatically with the currently read voltage. This automatically calibrates each Selector position.
Enable each gear position that is available on the selector by toggling on the Enable button.
Nominal Voltage
The voltage read by the selector position when the selector is in each position.
Voltage Tolerance
The voltage amount added either side of the nominal voltage for the current position. If the voltage of the selector falls within this distance from the nominal voltage, the selector is considered to be in the current position