Flat Shift
Flat Shift Wiring
Wiring This node allows you to assign an ECU Input for the Flat Shift switch. Any available AVI or SPI may be used.
Throttle Blip Gear Tolerance
Throttle Blip Gear Tolerance This table is only available if the Gear Tolerance Enable is onin the Flat Shift function. This setting is used by the Throttle Blip Gear channel to determine whether a vehicle is in gear or not at any point in time. This ...
Throttle Blip Duration
Throttle Blip Duration Table Only available if Throttle Blip is enabled. The amount of time (in ms) for the blip to occur. A cell value of 1000 will incur a blip of set percentage to occur for 1000ms, or until a conditional setting forces an exit. Up ...
Throttle Blip Amount
Throttle Blip Amount Table Only available if Throttle Blip in enabled. The commanded throttle position percentage. During a blip event, the throttle will open to this throttle position unless a conditional setting forces an exit. Up to 3D tuning is ...
Recovery Time
Flat Shift Recovery Time Available when the Recovery Method involves a Ramp Out. This is the amount of time that the cuts and/or ignition corrections will take to recover completely after a flat shift event. Typically in the 10 to 100ms range. Up to ...
Torque Reduction Time
Flat Shift Torque Reduction Time This table set the amount of time (in ms) that flat shift will make a full Torque Reduction. Up to 3D tuning is available. If in Timed Mode: The total amount of time to use full Torque Reduction. If in Closed Loop ...
Ignition Retard
Flat Shift Ignition Retard Available when the Flat Shift Cut Type is set to Ignition Retard. This allows for up to 3D (8x8) mapping of ignition retard to be used to limit engine power during flat shift.
Cut Percentage
Flat Shift Cut Percentage Table Available when the Flat Shift Mode includes fuel and/or ignition cuts. This allows for up to 3D (8x8) mapping of the percentage cut to be applied during a flat shift in order to reduce torque.
Load Cell
The Load Cell node is only available if Trigger Options > Input Select is set to Load Cell. Load Cell Up shift Voltage - This is the voltage read by the ECU from the Load Cell when the shifter is in the up shift position. To calibrate this voltage, ...
Conditional Trigger
Flat Shift Conditional Trigger When Flat Shift Switch is On - And/Or allows conditions to be combined so that multiple conditions must be met to enable the Flat Shift. Select - Select the ECU channel to be used. Maths - A selection of Equal To, Not ...
Flat Shift
Flat Shift The Flat Shift function allows for full throttle gear changes to occur without throttle lifting. There are a number of types of Flat Shift but this is commonly used for sequential gearboxes with an input from a load cell. The engine power ...